Standard Panels
10 Panel Standard
Summary
A comprehensive 10-panel lab screen adding methaqualone to the 9-panel coverage.
Why it matters
A lab-based urine screen with confirmation testing. Positive screens are confirmed before reporting, giving results suitable for employment and clinical use.
What this panel screens for
10 substances included in this panel.
Amphetamines (AMP)
Stimulants including amphetamine and prescription drugs like Adderall.
Cutoff: 1000 ng/mL
Barbiturates (BAR)
Sedative drugs such as phenobarbital.
Cutoff: 300 ng/mL
Cocaine (COC)
Cocaine and its primary metabolite.
Cutoff: 300 ng/mL
Benzodiazepines (BZO)
Sedatives such as Xanax, Valium, and Ativan.
Cutoff: 300 ng/mL
Methaqualone (MTH)
A sedative-hypnotic drug (Quaalude).
Cutoff: 300 ng/mL
Methadone (MTD)
A long-acting opioid used for pain and addiction treatment.
Cutoff: 300 ng/mL
Extended Opiates (4)
Morphine, codeine, hydrocodone, and hydromorphone — broader than a standard opiate screen.
Cutoff: 2000 ng/mL
Phencyclidine (PCP)
PCP, a dissociative drug also known as 'angel dust.'
Cutoff: 25 ng/mL
Propoxyphene (PHN)
A prescription opioid pain reliever (Darvon).
Cutoff: 300 ng/mL
Marijuana (THC)
The active compound in cannabis.
Cutoff: 50 ng/mL
All amphetamine positives include D/L methamphetamine isomer testing. Cutoffs shown are screening levels.